نتایج جستجو برای: Beam-Column Connection

تعداد نتایج: 281159  

Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...

Journal: :مهندسی سازه 0
محسن علی بخش

beam to column welded connection with radius cut on beam flange is known as rigid connection that provides acceptable ductility for special moment resisting frame (smrf). in order to decrease the cost of construction and to provide an easy-to-construct structure, the new method is available for reducing the beam section based on drilling on beam flange , known as drilled flange connection (dfc)...

Journal: :international journal of civil engineering 0
r. vidjeapriya department of civil engineering, college of engineering guindy, anna university, chennai, sardar patel road, guindy, chennai, india v. vasanthalakshmi department of civil engineering, college of engineering guindy, anna university, chennai, sardar patel road, guindy, chennai, india k. p. jaya department of civil engineering, college of engineering guindy, anna university, chennai, sardar patel road, guindy, chennai, india

the present study focuses on the performance of precast concrete beam-column dowel connections subjected to cyclic loading by conducting experiments. in this study, one-third scale model of two types of precast and a monolithic beam-column connection were cast and tested under reverse cyclic loading. the precast connections considered for this study is a beam-column connection where beam is con...

Journal: :مهندسی سازه 0
ابوذر صالح

the basic strategy of reduce the ductility demand and related concentrated tensions at moment resistance connections is reduce the section of the beam at connected region to column. by this method plastic hinge done at the reduced cross section and this local reduction decreases the demand of the components of connection. on this basis, in present study a new beam-to-column moment connection wi...

This paper evaluates the effect of slot existence with limited length between flanges and web junction of I-shaped beams at the region of moment connections on vertical force and shear stress distribution in beam flanges and web at connection section in comparison with classical theory of stress distribution. The main purpose of this research is to evaluate the efficiency of the slot in connect...

N. Fanaie , S. Kazerani, S. Soroushnia,

Abstract: Reduced Beam Section (RBS) and Drilled Beam Section (DBS) are seismic moment resistant frame connections, introduced after 1994 Northridge earthquake. RBS connection has been tested under cyclic loading and showed acceptable performance. In this paper, seismic behavior of Drilled Beam Section (DBS) connection is studied numerically using finite element method. A drilled beam section ...

Journal: :journal of the structural engineering and geotechnics 0
maziar basirololoomi m. sc student, department of civil engineering, eslamshahr branch, islamic azad university, tehran, iran armin aziminejad assistant professor, department of civil engineering, science and research branch, islamic azad university, tehran, iran. fariman ranjbaran assistant professor, department of civil engineering, eslamshahr branch, islamic azad university, tehran, iran

moment-resisting frames have extensive usage in earthquake-prone areas and high ability in energy dissipation.after the earthquake in northridge 1994,kobe 1995 fixed connections of steel structures have shown poor performance and generally they were caught brittle fracture of beam flange weld to the column.in order to remedy to avoid similar situations in future earthquakes,researchers introduc...

In this study, the behavior characteristics of I beam-to-concrete filled tube (CFT) column connection is studied through experiment and finite element models under the monotonic loading. To validate the finite element modeling, at first, an experimental model is made and experimented. After validation of the finite element modeling, different models were created in the software. The studied par...

Mohammad ali Faridalam, Fakhredin Danesh,

Geometry of eccentrically braced frames (EBFs) in some cases causes the connection of link beam to the column. The details of such conditions should be studied carefully due to the full plastic rotation in the link beam. In this research, the behavior of link-to-column connection is modeled and the failure modes are considered. Based on the previous researches shear link can exhibit better beha...

نمودار تعداد نتایج جستجو در هر سال